Mid-Continent Instruments and Avionics, Wichita, KS
REV. B, October 31, 2012 44 Manual Number 9017782
FIGURE 5.2
The altimeter instrument has failed, possibly due to exceedance of
the pressure sensor range. This may self-correct, but if the error
persists, immediately have the unit serviced.
FIGURE 5.3
The airspeed instrument has failed, possibly due to exceedance of
the pressure sensor range. This may self-correct, but if the error
persists, immediately have the unit serviced.
FIGURE 5.4
The airspeed and altimeter display have both failed due to
exceedance of their respective sensor ranges. This may self-
correct, but if the error persists, service unit immediately.
FIGURE 5.5
Battery failed initial capacity check. This may be due to recent
battery usage without allowing time to recharge. This may also
occur during extreme temperature conditions. User may
acknowledge this error and continue operation, but available
backup power capacity may be less than required minimum levels.
If this warning persists, the battery will need serviced.
FIGURE 5.6
This message is displayed when power is removed at low airspeed
(typical ground condition). The pilot has 60 seconds to confirm to
remain on, otherwise the unit will automatically power off to
conserve battery.