Mid-Continent Instruments and Avionics, Wichita, KS
REV. B, October 31, 2012 45 Manual Number 9017782
FIGURE 5.7
The configuration module has failed or is not installed properly.
Internal settings will be used. If the configuration module is
installed, it should be serviced immediately.
FIGURE 5.8
Internal failure. Service unit immediately.
FIGURE 5.9
Internal failure. Service unit immediately.
FIGURE 5.10
Internal (unit) and external settings (configuration module) failure.
It is unlikely that both settings would be lost. Try to reconfigure
the unit. Service unit if this error persists.
FIGURE 5.11
Internal (unit) settings were found to be invalid. The configuration
module settings will be copied to internal memory. Service unit if
this error persists.