15
Description
11
10
Wireless button
(On some models)
Press and hold on the POWER button for 3 seconds to initiate the
Wireless connection mode. The LED DISPLAY shows’AP’ to indicate
you can set Wireless connection. If connection (router) is successful
within 8 minutes, the unit will exit Wireless connection mode
automatically and the Wireless indicator illuminates and the unit
enters the previous function. If connection is failure within 8 minutes,
the unit exits the Wireless connection ·mode automatically.
Display
Shows the set % humidity level from 35% to 85% or auto start/stop
time (0~24) while setting, then shows the actual(±5% accuracy)
room % humidity level in a range of 30% RH(Relative Humidity) to
90% RH(Relative Humidity).
Error Codes:
EH60-Room temperature r sensor error--Unplug the unit and plug it
back in. If error repeats, call for service;
EH61-Tube Temperature sensor of the evaporator error-- Unplug the
unit and plug it back in. If error repeats, call for service;
EH0b-Display board and master control board communication error.
Unplug the unit and plug it back in. If error repeats, call for service;
Protection Code:
P2-Bucket is full -- Empty the bucket and replace it in the
right position.
Eb-Bucket malfunction--Replace the bucket in the right position, the
malfunction clear.
NOTE: When one of the above malfunctions occurs, turn o the unit,
and check for any obstructions. Restart the unit, if the malfunction is
still present, turn o the unit and unplug the power cord. Contact the
manufacturer or its service agents or a similar qualified person
for service.
Other Features
Auto Defrost
When forst builds up on the evaporator coils, the
compressor will cycle o and the fan will continue to
run until the frost disappears.
Note: When Auto defrosting operation, the unit may
make a voice of refrigerant flowing, it is normal.
Auto Shut O
The dehumidifier shuts o when the bucket is full.
For some models, the fan motor will continue to run
for 30 seconds.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
operation in the first 3 minutes.This is to protect the
unit. Operation will automatically start after
3 minutes.
Auto-Restart
If the unit breaks o unexpectedly due to the power
cut, it will restart with the previous function setting
automatically when the power resumes.
Smart dehumidifying mode(On some models)
Continuous dehumidifying mode
At continuous dehumidifying mode, the unit
dehumidify continuously and cannot select humidity.
Press mode button to exit continuous dehumidifying
mode.
At smart dehumidifying mode, the unit will
automatically control room humidity in a comfortable
range 45%~55% according to the room temperature.
The humidity setting function will be invalid.