Service manual for Dryer Machine Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
- 32 -
2) Igniter sparks but no gas ignition
Turn off power supply.
Using an ohmmeter, check the following:
3) Gas ignited but flame goes off
If a normal ignition takes place and after a short while the flame goes out, check the following:
Does secondary coil continuity?
Does holding coil show continuity?
Does wiring show continuity?
Does flame switch show continuity?
Check if flame switch contacts open
prematurely.
Check gas supply line pressure.
Is it in range?
Visually inspect gas valve coil. Is it burned
due to high temperature?
Contact gas company to
resolve.
Does hi-limit thermostat show continuity?
Check room ventilation. Is there enough air
supply to support burner flame?
Replace gas valve assembly.
Replace hi-limit thermostat.
Ensure proper ventilation.