• The appliance is intended to be permanently connected to the water mains and not connected by a hose-set.
• Whenusingtheo-peakfunction,theproductcanonlyworkundertheo-peakpowersupplyallthetime.
About Fluorinated Gasses
• Thisair-conditioningunitcontainsuorinatedgasses.For specicinformationonthetypeofgasand theamount,
please refer to the relevant label on the unit itself. Compliance with national gas regulations shall be observed.
-Installation,service,maintenanceandrepairofthisunitmustbeperformedbyacertiedtechnician.
-Productuninstallationandrecyclingmustbeperformedbyacertiedtechnician.
- If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months. When the
unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
• This appliance can be used by children 8 years old and above and persons with reduced physical, sensory or mental
capabilitiesorlackofexperienceandknowledgeiftheyaresupervisedorgiveninstructiononusingtheunitinasafe
manner and understand the hazards involved. Children should not play with the unit. Cleaning and user maintenance
should not be done by children without supervision.
• Children should be supervised to ensure that they do not play with the appliance.
• Ifthesupplycordisdamaged,itmustbereplacedbythemanufatureroritsserviceagentorasimilarlyqualiedperson.
• ConcerningdisconnectionincorporatedinthexedwiringshouldbeinaccordancewithAS/NZS3000.
• DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste seperatelly for special
treatment is necessary. Do not dispose of electrical appliances as municipal waste, use seperate collection facilities.
Contact your local goverment for information regarding the collection systems available. If electrical appliances are
disposedofinlandllsordumps,hazardoussubstancecanleakintothegroudwater and get into the food chain,
damaging your health and well-being.
• The wiring must be performed by professional technicians in accordance with national wiring regulation and this circuit
diagram. An all-pole disconnection device which has at least 3mm seperation distance in all pole and a residualcurrent
device(RCD)withtheratingnotexceeding30mAshallbeincorporatedinthexedwiringaccordingtothenationalrule.
• Conrmthesafetyoftheinstallationarea(walls,oors,etc.)withouthiddendangerssuchaswater,electricity,and
gas.
• Before installation, check whether the user’s power supply meets the electrical installation requirements of unit
(including reliable grounding, leakage, and wire diameter electrical load, etc.). If the electrical installation requirements
oftheproductarenotmet,theinstallationoftheproductisprohibiteduntiltheproductisrectied.
• Wheninstallingmultipleairconditionersinacentralizedmanner,pleaseconrmtheloadbalanceofthethree-phase
power supply, and multiple units are prevented from being assembled into the same phase of the three-phase power
supply.
• Productinstallationshouldbexedrmly.Takereinforcementmeasures,whennecessary.
• Generally, the ambient air temperature of the unit must be above -15°C and below 43°C.
• Install safety valve to water inlet, the largest torque of safety valve shouldn’t be more than 80N.m.
• Please make sure water tank is upright put. Install in the place that can prevent unit toppling and falling(e.g. balcony or
corner). If install the unit in an open space, to avoid being blown down by strong wind (especailly in the are with strong
wind),pleasexwatertankaccordingtooperationmanual.
• Allthediagramsinthismanualisforreferenceonly,itsappearanceandfunctionmaydierentfromwaterheaterthat
you bought, actual model shall prevail.
NOTE
CAUTION