During installing, it is necessary to reserve enough installation space and maintenance space according to the following
gures.
NOTE
≥300mm
≥1500mm
Air outlet
Fig 3-1
≥600mm
Use bolt to fix
≥200mm
≥600mm
≥200mm
≥500mm
07
3 BEFORE INSTALLATION
3.1 Accessories
Table 3-1
Accessory Name Qty. Shape
Purpose
Outdoor unit
Installation manual 1 Need by master unit
Manual of wired controller 1 Wired controller instructions
Wired controller components 1 Control unit and display unit status
Water drainage connection 1 For condensate water draining
Water drainage pipe 1
___
Condensate water drainage of unit bottom plate
Plasticexpansiontube 4
___
Toxmountingbox
Screw 4
___
Toxmountingbox
FixingboxofHMI 1 Install the wired controller
Wiring for HMI 1
___
Connect the unit and HMI
Seal ring 1
Sealbetweenwaterdrainageconnectionandexternalmachine
Water tank
Watertankxingstrip 1 Fixedwatertank
PTR valve 1 Pressure relief
Connector 2 Connect water tank and safe care
Seal ring 2 Prevent rust between water tank and joint
Safe care 2 Isolationcurrenttosomeextent(onlywithAux.*)
Copper nut 2 Refrigerant connection pipe nut of water tank
3.2 Space for maintenance
3.2.1 Outdoor unit installation and maintenance space, see Fig 3-1 and Fig 3-2. (Unit: mm)