www.midtronics.com
8 – Manual Charge
DCA-8000
35
8 – Manual Charge
Manual Charge
Use Manual Charge to charge a battery using user-selectable parameters
including voltage, current, or time.
At any time during the test tap to return to the previous screen or to return to the Main Menu.
1. Connect the Diagnostic Device test clamps to the battery.
2. At the Main Menu tap Manual Charge. The Edit Battery Information
screen is displayed.
3. Enter the battery information and charging parameters.



Charge Limit
Voltage
Rated Ah






Timed

CCA
Time Value
60

590

135
Reset

NOTE: See Appendix B for complete parameter descriptions.
If the displayed information is correct, tap Continue to begin the Battery Test. Tap on the
corresponding box to edit the parameter information.
The charger goes through a series of steps to determine the overall condition of the battery
before applying a charge. Those steps include measuring ambient temperature, Cranking
Health, Reserve Capacity, Charge Acceptance, and applying a Load Test on the battery.
Manual Charge Results
Manual Charge
 
 
 
 
  F
Send Results
Done
The test results are displayed on the charger screen.
To send the test results to a congured printer or via email tap Send Results and select an option.
To return to the Home Screen, tap Done
or to return to the Main Menu.