EasyManua.ls Logo

Miele S 8530 - Fault Repair: Motor Does Not Run; Causes for Motor Not Running

Miele S 8530
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
x
Note
1. Super AirClean
This exhaust filter must always be changed when a new packet of Miele
dustbags is opened. Each package of Miele dustbags includes a Super Air
Clean exhaust filter.
2. Active AirClean – Active HEPA
This exhaust filter must be changed once a year. The date of replacement
can be written directly on the filter.
3.2 Motor Does Not Run
Cause
Park switch jams after pulling out the suction hose.
Remedy
A Check the Park switch function.
A If necessary, replace the Park switch; see Park Switch Replacement (Model-
Dependent), 040 4.5.
Cause
Motor winding defective.
Remedy
A Operating Unit Removal, 040 4.1.
A Check motor winding continuity.
A If no continuity, see Motor Replacement, 050 4.2.
x
Note
When removing the operating unit, the plugs between the operating unit and the
motor will also be disconnected. These plugs must be lined up exactly when re-
inserting the operating unit so that they can be snapped into place.
Cause
The motor winding is too hot and the thermal protection function has tripped.
Descriptive Technical Documentation
050-4 DTD no. 41-8000
This information should not be duplicated or passed on without Miele approval. All rights reserved. 07.06.2013, US_am