20
TECHNICAL DATA
Type DELTA 140E DELTA 160E
Mains voltage 1x230 V ± 10% 1x230 V ± 10% V
Fuse 16
20 (16)
1
A
Mains current, effective 16,0 20.1 A
Mains current max. 30.0 35.0 A
Consumption, 100% 3.5 4.6 kVA
Consumption, max. 6.9 8.1 kVA
Consumption, open circuit <35 <35 W
Efficiency 0.85 0.85
Current range DC 10 – 140 20 – 160 A
Duty cycle, 100% 40 (20) °C 90 (120) 100 (120) A
Duty cycle, 60% 40 (20) °C 120 (140) 120 (150) A
Duty cycle, 40 (60)% 40 (20) °C 140 A
Duty cycle, 30 (35)% 40 (20) °C 160 A
Open circuit voltage 55 – 60 55 – 60 V
2
Protection class
IP23 IP23
3
Application class
S
S
Standards EN/IEC60974-1
EN/IEC60974-10 (Class A)
Extension cable min. 2.5 mm²,
max. 30 m
min. 2.5 mm²,
max. 30 m
Electrode diameter 1.6 – 3.25 1.6 – 3.25 mm
Dim. HxWxL 230 x 150 x 370 230 x 150 x 370 mm
Weight 7.0 7.0 kg
Circuit diagram
1 2 3 4 5 6
A
B
C
D D
C
B
A
Title
umber Revisi on Size
B
Date: 19-Feb-2007 Shee t of
File : Drawn By:
1
2
3
4
P1
P2
EI-2 5
P1
P2
GN
D
2
VOUT
3
VINT
1
LM7812
A
-
+
23
27
29
25
2
4
13
6
1
11
21
30
15
10
9
23
27
29
25
2
4
13
6
1
11
21
30
15
10
9
1
2
3
4
10K
+12V
10K
RED
+24V
+12V
1
2
XH-02
+24V
1
2
VH-0 2
+24
OUT+
OUT-
B-XQDB
+24
SW1
SW1
P
-02-A0
DELTA 130E/160E
GREEN
1
With connection to low voltage mains network only 16A (schuko plug)
2
The machine is designed for outdoor applications as it meets the demands of protection class IP23.
3
This machine meets the demands made for machines which are to operate in environments with an increased
hazard of electric shocks.