Sensor Calibration
A.
A.A.
A. Description: For better accuracy, please execute calibration immediately after
installed sensor each time.
Step 1. Fix sensor, keep 1mm gap from tape
(RECOMMENDED).
Step 2. Press
Target value display GO (Enter
parameter)
Step 3Press and hold or to start.
NoteMoving the slider at low speed, Required
distance around 120mm (Moving GO )
Display:
GO
(Detecting)
Display:
GO
(Almost complete)
When completed calibration, LED display will flash and
show.
Note: Please reload origin datum values refer to
page8.
GO
-
8 8 8 8 8 8
-
8 8 8 8 8 8
GO
9
9
F
8
9
Gap sensor-tape