OM-2228 Page 11
SECTION 4 − INSTALLATION
4-1. Specifications
. For any single or three phase voltage from 208 V to 575 V, the Amperes Input at Rated Load Output is the same for 50 Hertz or 60 Hertz input
power. For example, the amperes input for 230 V, 50 Hz, single-phase input power is 33 amperes. The amperes input for 230 V, 60 Hz, single-phase
input power is also 33 amperes.
60 Hz
Amperes Input at Rated Load
Output 60 Hz
Rated
Output
Type of
Output
Plasma
Gas
Rated
Cutting
Capacity
Maximum
Open-
Circuit
Voltage DC
208 V 230 V 460 V 575 V KVA KW
Single-
Phase
36 33 16 13 7.5 7.4
55 A @
110 Volts
DC, 50%
Duty Cycle
Direct
Current,
Straight
Polarity
(DCEN)
6.0 CFM
(172
L/min) At
70 PSI
(483 kPa)
Air Or
Nitrogen
Only
0.875 in.
(22 mm)
At 10 IPM
280
3-Phase 21 20 9 8
7.6
(7.9 for
575 V
input)
7.4
55 A @
110 Volts
DC, 60%
Duty Cycle
50 Hz
Amperes Input at Rated Load
Output 50 Hz
Rated
Output
Type of
Output
Plasma
Gas
Rated
Cutting
Capacity
Maximum
Open-
Circuit
Voltage
DC
230 V 380 V 400 V 415 V KVA KW
Single-
Phase
33 − − − − − − 7.6 7.4
55 A @
110 Volts
DC, 50%
Duty Cycle
Direct
Current,
Straight
Polarity
(DCEN)
6.0 CFM
(172
L/min) At
70 PSI
(483 kPa)
Air Or
Nitrogen
Only
0.875 in.
(22 mm)
At 10 IPM
280
3-Phase 20 10 10 10 7.6 7.4
55 A @
110 Volts
DC, 60%
Duty Cycle