press
"ENTER"
[P6 0.000]
displayed, Belt Length = 0
key in value, (Belt Length, as measured or from Design Data Sheet)
press
"ENTER"
[P7 ####]
displayed, Test Load = 100% Design Load
key in value, (Test Load, from Design Data Sheet. Refer to the associated belt scale instruction manual.)
press
"ENTER"
Zero Calibration
If the actual belt speed is 10% or less than the Design Belt Speed
(P4), the calibration will be aborted.
[oF 0]
will be displayed.
Run the empty belt at normal operating speed for some time to limber up the belt (at least 10 minutes).
press
"ZERO"
[oo 0]
displayed
press
"ENTER"
, all 4 display mode LED’s will be illuminated,
[oo ####]
displayed, wait (time dependent on value of P30)
[od 0.000]
displayed, Zero Deviation
press
"ENTER"
[oC ####]
displayed, Initial Zero Reference Count
Span Calibration
If the actual belt speed is 10% or less than the Design Belt Speed (P4),
the calibration will be aborted.
[SF 0]
will be displayed.
Suspend the Test Weight(s) from the scale calibration weight bracket or place the test chain on the belt.
Refer to the associated belt scale instruction manual.
Run the conveyor at normal operating speed.
press
"SPAN"
[SP 0]
displayed
press
"ENTER"
, all 4 display mode LED’s will be illuminated and
[SP ####]
displayed, wait (time dependent on the value of P30)
PL-516 32