© 2014 MIMAKI ENGINEERING CO.,LTD. 3.1.2 P.2
3.1.2 Main Unit Specification (for 300 series)
1
2
3
4
Origin position matching
(LED pointer)
Positioning by the LED pointer mounted on the head actuator
• Pointer is used when printing origin is changed from default
value
Distance
accuracy
Absolute accuracy
±
0.3 mm or
±
0.3% of specified distance, whichever is larger
Excluding test media photo paper glossy
paper contraction and expansions
Excluding initial meandering
Repeatability
±
0.2 mm or
±
0.1% of specified distance, whichever is larger
Squareness
±
0.5 mm/1000 mm
Media skew 5 mm or less/10 m
Print gap Manual 3 step adjustment(2.0/2.5/3.0) +1mm or +2mm, selection
at install,
Media heater PRE/PRINT/AFTER :60 / 60 / 60
3 system independently control
MCT 2 path installed
UISS Installed
Washing cartridge Installed
NCU (nozzle missing detect) Installed
Media severing Y-axis cut by head cutter
Severing precision (misalignment) 0.5 mm or less
Cutting tool is an expendable item.
Waste ink tank Bottle type (2000 ml)
Image decompression memory SD-RAM 256MB
Interface Mounted standard USB2.0 * Cable supplied
Ethernet: 100BASE-TX (For output printing status)
Command MRL-IV
MAPS MAPS3
Displayable language Japanese/English
Noise Standby 51 dB or less. (FAST-A, at 1 m from the front, rear, right and
left side of the machine)
During operation 65 dB or less
Discontinuous
operation
75 dB or less
Compliance with standards 1)VCCI class A
2)FCC class A
3)UL 60950-1
4)CE Marking (EMC Directive , Low Voltage Directive and
Machinery Detective)
5)CB report
6)RoHs
REACH, Energy Star
Power supply and power
consumption
AC100 to 120 V 1440 W or less, AC220 to 240 V 1920 W or
less, 50/60 Hz±1 Hz
• Input manual switching
• With remote SW function
• With sleep function mode
Inlet1; control + heater (after)
Inlet2; heater (pre / print)
Power consumption 1440 W x 2 (AC100 - 120 V) or less Main unit, including heater
excluding options
Ambient con-
ditions
Service
temperature range
20
C - 35
C Ink discharge stability can drop
under any ambient conditions
exceeding the specified limits.
Relative humidity 35 % - 65 % Rh (no condensation)
Quality assurance
temperature
20
C - 25
C
Temperature
gradient
±
10
C/h or less
Dust
0.15 mg/m
3
(Equivalent to the atmosphere in offices)
Option
1)Drying Fan unit (Use separately power supply)
2)Sticking prevention net
3)AMF unit (Standard installed for aq model)
Item
Specification
Remarks
CJV300-130 CJV300-160
R.1.0
Service Documents > Basic Specification > Main Unit Specification > Main Unit Specification (for 300 series)
Model
CJV300
Issued
2014.09.15
Revised F/W ver
Remark
1.0