4.1.1 Service Mode and Specialized Key
Indication on LCD
Outline
For troubleshooting or maintenance work, the machine needs to be operated in service mode.
The following describes the Specialized Key functions which start this machine in service-related mode.
Specialized Key Functions
After the start of the machine, press the specific key(s) on the operation panel while the version information is
displayed. Then the machine will enter the corresponding one of the following service-related modes.
Service Mode
For maintenance work, start the machine in service mode. Then you can use the functions that are not available in
normal mode. As for those functions, the "#" mark is added at the head of the function name.
Service-related mode How to enter Remarks
F/W Update
(While version information
is displayed)
Press [ENTER]
Receives FirmwareROM data from the host PC via USB2.0 I/F, and
updates the firmware of the main PCB.
Available only when the machine is started by turning on the main
power.
After firmware update, restart the machine by turning the main
power.
Parameter
UP/DOWNLOAD
(While version information
is displayed)
Press []+[]
Uploads the parameters and log data from the machine to the host PC
via USB2.0 I/F.
Downloads the parameters and log data from the host PC to the
machine via USEB2.0 I/F.
System Parameter input
(While version information
is displayed)
Press []+[]
Start the machine in [SYSTEM PARAM.] input mode of
[#PARAMETER].
When the machine cannot start because of a parameter hash error or
the like, the parameters can be initialized in this mode.
When the machine cannot be operated because of a system down
error or the like, input the system parameter No. 45 HASH 0 1 or 2
in this mode. Then the machine can be started for the purpose of
checking for problem.
Service mode (While version information
is displayed)
Press [FUNC1]+[FUNC3]
Active until the power to the machine is turned off.
System parameter
SUPPORT 0 2
(3: English version)
Active until the value of the system parameter No. 122 SUPPORT is
changed to 0.
When installing the
device-specific F/W
into new product main-
tenance PCB (common
PCB)
(While version information
is displayed)
Press [FUNC2]
Install the device-specific F/W into new product maintenance PCB
(common PCB).
In normal mode
CJV300-160
  
start-up
V1.
0
0