F/W update procedure after the replacement of the main circuit board
Outline
This section shows the procedure for F/W updating after the replacement of the main circuit board.
Update procedure
Step Operation Description
1 Parameter upload Refer to “4.1.3 Parameter Up/Download
2 Replace the main PCB Replace the main PCB
3Power ON
Turn the power ON
4 F/W update Update F/M to the same version of F/W when uploading the parameter.
Refer to “4.1.2 F/W Update
5
Initial the SYSTEM PARAMETER
Input system parameter INITIAL= “1” for initializing all parameters.
*1
*1.Make sure all parameters are initialized
6 Parameter download Download the parameter that is uploaded on the above step “1”.
Refer to “4.1.3 Parameter Up/Download