© 2014 MIMAKI ENGINEERING CO.,LTD. 4.1.4 P.1
1
2
3
4
R.1.0
4.1.4 Parameter Function
Outline
With the PARAMETER function, you can check and set parameters on the machine. (Available in service mode)
Parameter function items
Be sure to upload parameters before changing them.
There is a possibility that input errors may make recovery impossible.
No. Item Description Change
1 SYSTEM PARAMETER A group of parameters as a storage of adjusted values for each machine
(printing)
Partially
permitted
2 MAINTENANCE PARAMETER A group of parameters for firmware debugging and assessment in the
development stage
Partially
permitted
3 SERVO PARAMETER A group of parameters for XY motor control. Disap-
prove
*1
*1.Do not change the disapprove parameter without instructions from developer.
4 FEED PARAMETER A group of parameters for feed control. Disap-
prove
5 HEAD PARAMETER A group of parameters to save the dot position correction and the head
voltage (correction value)
Permitted
6 OPE PARAMETER A group of parameters for operation control. Disap-
prove
7 INK PARAMETER1 A group of parameters as a storage of the operation status of the
machine
Partially
permitted
8 INK PARAMETER2 Parameters for control of function related to ink system. Disap-
prove
9 DEBUG PARAMETER Parameters for evaluation of debug in development Disap-
prove
10 SCAN PARAMETER A group of parameters for scan control. Disap-
prove
11 NOZZLE RECOVERY PARAM-
ETER
Parameters to save nozzle numbers registered at nozzle recovery Disap-
prove
Service Documents > Technical Information > Basic Information > Parameter Function
Model
CJV150/300
Issued
2014.09.15
Revised F/W ver
1.10
Remark
1.0