9
8
Return the wiper to its original position.
Insert the wiper by holding both the ends.
Protrusion
9
Clean the cap rubber and cap rubber cover.
Wipe off any ink on the cap rubber and the cap rubber cover using a clean stick soaked in washing
liquid.
Wipe it off properly so that there is no residual washing liquid.
Cap rubber
Cap rubber cover
Clean the wiper and the bracket until they look like the picture.
After cleaning, make sure the cap rubber and the mesh inside the cap have not come off.
10
Once the cleaning is complete, press the [ENTER] key.
After the initial operation, the display returns to Step 1.