Warning / Error Messages
5-12
Message Cause Solution
An abnormal temperature of the
head heater was detected.
Turn off the main power to the machine
and turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The head heater is disconnected.
Trouble has occurred with the
thermistor of the head heater.
An error was detected during scan-
ning operation.
A system error occurred.
**** ERROR 211 ****
HeadWARM.TEMP.(----)
**** ERROR 211 ****
HeadWARM.BREAK(----)
**** ERROR 211 ****
HeadWARM.THERM(----)
**** ERROR 250 ****
YCOORDINATES
**** ERROR 251 ****
SYSTEM ERROR