© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.12 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Test Items > Test Function > [HEATER TEST] SSR
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
5.1.12 [HEATER TEST] SSR
Function
ON/OFF test of heater is executed.
Operation Procedures
Step Item Description Remarks
1 ON/OFF setting Designates ON/OFF of Pre, Print and After Heater. Temperature is not controlled.
2 ON/OFF display [FUNCTION]:Returns to setting screen.
Temperature is displayed with a unit selected in the [UNIT SETUP] of the [MACHINE SETUP] function.
A/D conversion value is also displayed.