ZS3 Instructions for Use
121 | P a g e
Always examine transducers for damage, such as cracks, splitting, holes, or fluid leaks. If
damage is evident, discontinue use of the transducer and contact Mindray.
Prior to initiating any disinfection process, disconnect the transducer from the ultrasound
system.
Ensure that any connected external equipment, such as external monitors, printers and
peripherals, comply with relevant standards such as IEC60601-1 and IEC60601- 1-2.
If an external video monitor is connected to the ZS3 system, it is necessary to ensure that
an RF ferrite is clamped to the cable as close to the ZS3 system as possible. Use a ferrite
such as Fair- Rite Products Corp. 0431167281 (or an equivalent).
The potential equalization terminal, located by the AC Mains connection, is connected to
the system chassis. It can be connected to corresponding terminals on other equipment to
eliminate potential differences. Do NOT use it for additional protective grounding
Damage to the system may cause poor image quality, including possible imaging artifacts
sometimes referred to as ‘halo’ or ‘headlight’ artifacts. Regularly inspect the system for
damage and know how to recognize imaging artifacts.
There are many types of system use and system error messages that might be displayed
during the use of the ZS3 Ultrasound System. If a message is encountered that is not self-
explanatory, contact Mindray service for assistance.
Do not touch any of the connector contacts while performing a patient examination to
prevent the possibility of a hazardous current path.
Do not expose the device to a magnetic resonance (MR) environment.
Warnings – Ocular (Ophthalmic) Imaging
To avoid injury to the patient, use only the Ocular Preset when imaging through the eye.
The FDA has established lower acoustic energy limits for ophthalmic use. The system will
not exceed these limits only if the Ocular Preset is selected.
Warnings - Battery
To avoid electrical shock, do not touch the battery contact.
To avoid risk of fire, explosion, or burns:
Do not disassemble or alter the battery.
Do not short-circuit the battery by directly connecting the positive and negative terminals
with metal objects.
Do not heat or discard the battery in a fire.
Do not expose the battery to temperatures above 65° C (150° F).
Do not charge the battery near a heat source.
Do not leave the battery in direct sunlight.
Do not use a damaged battery.
Charge the battery at room temperature.
The battery should only be charged within the ZS3 System.
Inspect the battery for damage before charging or placing the battery in the ZS3 System.
Do not connect battery to an electrical power outlet.
Do not continue to recharge the battery if it does not recharge fully after 4 hours.