EasyManua.ls Logo

Minolta EP5000 - Memory Backup

Minolta EP5000
392 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interleaf EP5000/EP4000 GENERAL, MECHANICAL/ELECTRICAL
97.04.01
M-97
1156SBM2600A
MEMORY BACKUP26
IC1 (RAM) of RAM Board PWB-R connected to Main Control Board PWB-A stores
the setting/adjustment values set in the Tech. Rep. Modes as well as the counter
counts. Backup Battery BAT1 is mounted on PWB-R to prevent the contents of
memory from being lost when the power cord is unplugged or PWB-R removed from
the copier. BAT1 requires a voltage of 2V or more to retain the contents of memory.
Important
As we noted above, the RAM stores critical data. If PWB-R has been replaced with
a new one, memory must first be cleared and then all settings be made again. It
should also be noted that PWB-R should not be replaced at the same time when
PWB-A is replaced.