(5) Adjustment of Exit/Duplex Solenoid SL5
z Requirement
D With the lever in contact with the stopper (SL5 in the deenergized position), the gap between the plunger
rubber washer and the solenoid should be 4.0 to 4.5 mm.
z Important
D After the adjustment, move the plunger manually to check that it moves smoothly and the Switching
Plate swings up and down properly.
1134D122AA
3. Bring the lever into contact with the stopper. Keeping that position, move SL5 so that the gap between
the plunger rubber washer and solenoid measures 4.0 to 4.5 mm. When the specified dimension is
reached, tighten the two SL5 mounting screws.
1156D173AA
1. Open the Left Door.
2. Loosen two screws that secure SL5.