Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
S-6
<Clearing Procedures>
D Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec. open PJ2.
4. Check that the message “Initialize completed” is shown on the Touch Panel, then touch “Enter.”
D Memory Clear Test Point TP3
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 3 closed, turn ON the Power Switch.
3. In approx. 5 sec. open the circuit across TP1 and 3.
4. Check that the message “Memory Clear completed” is shown on the Touch Panel, then touch “Enter.”
NOTE
D If an erratic operation or display occurs, perform the clearing procedures in the order of PJ2 and TP3.
D When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
Clearing Method
Data Cleared
Front Door
Open/Close
Trouble Reset
Switch
(S1)
Initialize
Switch
(PJ2)
Memory Clear
Test Point
(TP3)
Misfeed display f f f f
Malfunction display (except
Exposure Lamp and fusing
system)
f f f f
Malfunction display (all includ-
ing Exposure Lamp and fusing
system)
* f f f
Erratic operation/display * * f f
User mode * * * f
Service mode * * * f
F5/F7 setting values * * * f
System Input * * * f
Accessory Test * * * f
Level History * * * f
Adjust mode * * * f
f : Cleared (initialized) *: Not cleared: