Loading...
Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-84
uC0921
Step Check Item Result Action
Does PC65 operate properly?
Using the IC Port Data Check function,
YES
Replace PWB-A.
1
make an input port check on PWB-A
(IC3A) APB1.
NO
Replace PC65 or PWB-M1.
uC0922, C0923
Step Check Item Result Action
Does PC69 operate properly?
Using the IC Port Data Check function,
YES
Replace PWB-A.
1
make an input port check on PWB-A
(IC3A) BPA2.
NO
Replace PC69 or PWB-M1.
uC0926
Step Check Item Result Action
1
Remove the Right Door, lift up the Lock
Lever with a flat-blade screwdriver to
unlock and slide out the 1st Drawer.
2
Is the Lock Release Spring installed
properly?
NO
Reinstall or change.
3
Are the Lock Lever and Torsion Spring
installed properly?
NO
Reinstall or change.