Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-103
1156SBT040227A
27)C0F30: ATDC Sensor UN3 Failure
C0F31: ATDC Sensor UN3 Failure
Relevant Electrical Parts
D ATDC Sensor UN3 D Master Board PWB-A
1156C19TAA
Step Check Item Result Action
1
Is the malfunction code “C0F30” dis-
played?
YES
Go to step 3.
2
Is the value for “ATDC Ref. Value” of
“Level History” equal to the value given
on the Adjust Label?
NO
Enter the value given on the Adjust La-
bel.
3 Is PWB-A PJ11A plugged in securely? NO Plug it in securely.
4 Is CN35 plugged in securely? NO Plug it in securely.
5 Is UN3 installed in the correct position? NO Reinstall.