Do you have a question about the MIR Spirolab and is the answer not in the manual?
Type | Spirometer |
---|---|
Connectivity | USB, Bluetooth |
Battery | Rechargeable |
Measurement Parameters | FVC, FEV1, PEF, FEF25-75% |
Power Supply | Battery or USB power |
General, safety, legal, and environmental considerations for the Spirolab service manual.
Covers technical specifications of the Spirolab unit and the standards it complies with.
Details the main board components, including the battery charging controller and its functions.
Describes room temperature sensor, USB communication port, and oximetry port functionalities.
Explains the display, printer, and turbine flowmeter modules and their operation.
Recommends annual checks and lists required tools and equipment for maintenance.
Outlines inspection checklists and functional testing procedures, including self-tests.
General safety and handling precautions for replacing sensitive components.
Details the Spirolab case parts and provides step-by-step instructions for opening the device.
Details procedures for removing and replacing internal PCBs and components.
Step-by-step guide for removing and reinstalling the display module.
Detailed procedure for replacing the battery pack, including safety warnings.
Instructions for removing and replacing the thermal printer.
Information on turbine types, handling, and cleaning procedures for the reusable turbine.
Covers internal software upgrades and turbine calibration instructions.
Instructions for checking and replacing the oximetry module.
Covers functional tests required after repairs for both hardware and software.
Checks to be performed on devices equipped with an oximeter.
Procedures for checking the assembled device casing and performing tests after repairs.
Details the procedures for performing spirometry and oximetry tests.
Outlines the specific checks for devices that do not have the oximetry function.
Lists tests performed on the PCB for devices without an oximeter.
Covers ordering spare parts, delivery procedures, warranty claims, and return shipments.
Troubleshoots issues related to device power, battery, and display not turning on.
Details troubleshooting steps for incorrect battery operation.
Addresses issues where spirometry measurements are not taken or are incorrect.
Troubleshoots issues with oximetry measurements, including connection and function.
Guides on troubleshooting problems with USB data communication.
Refers to Appendix C for component identification and PCB layout.