Do you have a question about the Mircom FleX-Net FX-2003-12NDS and is the answer not in the manual?
Brand | Mircom |
---|---|
Model | FleX-Net FX-2003-12NDS |
Category | Fire Alarms |
Language | English |
Overview of the FleX-Net™ system, its modular components, and network capabilities.
Highlights the system's capacity, modular design, network communication, and key operational aspects.
Defines 'circuits' as electrical interfaces and 'zones' as logical protected areas.
Describes how initiating and indicating circuits can be wired as Class A or Class B.
Details different main chassis models, their capacities, and mounting options.
Describes modules like FNC-2000, ANC-5000, and TNC-5000 for network communication.
Lists and describes adder modules like Quad Loop Adder and its daughter board.
Details various display modules used for system interaction and status indication.
Lists audio and telephone interface modules like paging and telephone control panels.
Details the addressable booster power supply unit used for system expansion.
Lists various enclosure types and their dimensions for mounting system components.
Describes remote annunciator modules used for system monitoring and control.
Details the FX-LOC(R) console for critical emergency information and mass notification.
Lists available battery types and their charging specifications.
Lists accessories like end-of-line resistor plates and external battery cabinets.
Provides detailed dimensions and knockout locations for the BBX-1024DS enclosure.
Details material and finish specifications for the BBX-1072ADS enclosure.
Provides installation instructions, dimensions, and material specifications for the BB-5008 enclosure.
Details dimensions, material, and finish for the BBX-1024XT(R) enclosure.
Provides steps for general chassis installation, including wire grouping and grounding.
Details dimensions and installation instructions for the BB-5014 enclosure.
Illustrates module mounting positions within FX-20XX-12NDS and FX-2009-12NDS main chassis.
Explains how display modules are mounted on various chassis types and enclosures.
Details jumpers, connectors, and switches for setting up the main fire alarm module.
Describes DSPL-420(DS) and DSPL-2440 modules and their connections.
Details FNC-2000, FOM-2000-UM modules for network and fiber optic communication.
Describes IPS, FDX, DM, SGM, RM, PR-300, UDACT modules and their settings.
Details ALCN-792MISO/D modules for adding addressable loops to the system.
Details terminal connections for the main fire alarm module, including RS-485 and auxiliary power.
Illustrates analog loop terminal connections for Class B, X, and A wiring configurations.
Shows Class A wiring for FNC-2000 modules and fiber optic wiring for FOM-2000-UM.
Details wiring for DM, SGM, RM, PR-300, UDACT modules and power supply connections.
Provides wiring run data for initiating circuits, NACs, and analog loops.
Lists pre-power-on checks, power-up procedure, and troubleshooting for system issues.
Explains panel indicators, common controls, single/two-stage operation, and circuit types.
Covers backup, query, fast-forward, graphic software, Ethernet port, and logic engine.
Explains how to configure nodes for mass notification and fire/central control groups.
Shows typical system layouts with audio, including main lobby panel and node connections.
Details components for integrated fire/audio cabinets, including main board and controller modules.
Describes the BBX-FXMNS enclosure, backbox, and mounting of vertical microphone/telephone modules.
Provides installation instructions for QBB-5001(R) cabinets, including module placement and power wiring.
Details installing, removing, wiring, and backup applications for QAA amplifiers.
Explains amplifier displays, controls, and operation for audio cabinet modules.
Covers amplifier installation, before power-on checks, and audio configuration steps.
Shows dimensions for BB-5008 and BB-5014 lobby backboxes for paging and telephone modules.
Details the ANC-5000 board, its wiring, and audio paging bus connections.
Describes QMP-5101NV vertical and QMP-5101N network master paging modules.
Explains controls and indicators for paging modules and selector panels.
Details TNC-5000 mounting, wiring, and setup for addressable telephone systems.
Describes QMT-5302NV vertical and QMT-5302N master telephone modules and their connections.
Details QAZT-5348DS/5302DS selector panels, their operation, and connections.
Provides detailed specifications for system components, modules, and accessories.
Guides calculation of power supply and battery requirements for system sizing.
Lists DIP switch settings for configuring node addresses and module settings.
Explains alarm verification timing intervals as per ULI/ULC standards.
Provides wiring diagrams for addressable supervised output modules.
Guides determination of power supply and battery requirements for audio components.
Describes FXMNS as Mass Notification System, its configuration, and emergency operations.
Details APB-200/COA sounder bases wiring to auxiliary power with supervision.
Provides critical warnings for readers and installers regarding system limitations and responsibilities.
Provides links to warranty, purchase terms, and software license agreements.