Do not stop the robot or apply emergency stop by turning the robot controller's
main power OFF. If the robot controller main power is turned OFF during
automatic operation, the robot accuracy could be adversely affected. Moreover,
it may interfere with the peripheral device by drop or move by inertia of the arm.
Do not turn off the main power to the robot controller while rewriting the
internal information of the robot controller such as the program or parameters.
If the main power to the robot controller is turned off while in automatic
operation or rewriting the program or parameters, the internal information of the
robot controller may be damaged.
Use the USB devices confirmed by manufacturer. In other case, it might have
care difficulty by the effect of temperature, noise and so on. When using it,
measures against the noise, such as measures against EMI and the addition of
the ferrite core, may be necessary. Please fully confirm of the operation by the
customer
C.Notes of the basic component are shown.
*SD series: CR1DA-700 series
Please install the earth leakage breaker in the primary side supply power supply
of the controller because of leakage protection.
CAUTION
CAUTION
CAUTION
CAUTION
保護アース端
(PE)
電源端子台
漏電遮断器
(NV)
端子カバー
端子カバー
アース接続
ネジ
コントローラ
Controller
Cover
Cover
earth leakage
breaker
Terminal
Earth screw
CR1DA series