3 Controller
Emergency stop input and output etc.
3-54
Fig.3-13 Connection of the special-stop-input
1A
2A
3A
4A
1B
2B
3B
4B
専用停力コタ(SKIP)
電線差込口(AWG#24-18)
イナスドライバ差込口
SKIP
フェライトコア(付属品
2回通し
300mm以
<CR1DA-771/CR1DA-771-S15>
Special stop connector (SKIP)
* Please remove the contact
capacity seal currently stuck
on the connector, and
connect.
Minus driver plug area
Electric wire plug area(AWG#24-18)
<The connector connection method>
The electric wire skins covering 7mm.
In the condition that the minus driver is inserted, insert the electric wire, and remove the minus driver.
The electric wire is locked by the connector.
within 300mm
Ferrite core
(attachments)
Pass twice
* The figure is CR1DA-771.
(CR1DA-771-S15 is the same.)