7 Buffer Memory
7.3 Positioning Parameters
63
FX3U-1PG User's Manual
1
Introduction
2
Specification
3
System
Configuration
4
Installation
5
Wiring
6
Before Starting
Positioning
Operation
7
Buffer Memory
8
Manual Control
9
Positioning
Control
10
Program
Example
7.3.10 [BFM#14, #13] Zero-point address
Set the zero-point address when the zero return operation is completed.
When the zero return operation completes, this value is written to the current address.
For the zero return operation, refer to Section 8.3.
Point
Value is in user units and includes the position data multiplier.
When the extension positioning parameter is used, use the zero-point address (BFM#50, #49).
7.3.11 [BFM#15] Acceleration/deceleration time
Set the time required to accelerate from the bias speed to the maximum speed (decelerate from the
maximum speed to the bias speed).
For details on the acceleration/deceleration time, refer to Section 6.2.
Point
When the extension positioning parameter is used, use the acceleration time (BFM#51) and the deceleration
time (BFM#52). It is necessary to set the acceleration time (BFM#51) and the deceleration time (BFM#52)
individually.
BFM No.
Description R/W Default
High order
16bit
Low order
16bit
#14 #13
Setting range: -2,147,483,648 to 2,147,483,647 (user unit)
Set the value within -2,147,483,648 to 2,147,483,647 PLS in the converted pulse data.
R/W K0
BFM No.
Description R/W Default
High order
16bit
Low order
16bit
-#15
Setting range:
Trapezoidal acceleration/deceleration: 1 to 32,767 ms
Approximate S-shaped acceleration/deceleration: 1 to 5,000 ms
R/W K100