8 Manual Control
8.2 JOG Operation
83
FX3U-1PG User's Manual
1
Introduction
2
Specification
3
System
Configuration
4
Installation
5
Wiring
6
Before Starting
Positioning
Operation
7
Buffer Memory
8
Manual Control
9
Positioning
Control
10
Program
Example
3. Speed change during the JOG operation
When changing the JOG speed during the JOG operation, use the operation speed change function.
However, the operation speed cannot be changed during the inching operation.
→ For details of the operation speed change function, refer to Section 6.6.
Setting items of JOG operation
BFM No.
Setting items
Positioning
parameter
Extension
positioning
parameter
#0 #34, #33 Pulse rate
#2, #1 #36, #35 Feed rate
#3 b1, b0 #37 b1, b0
Operation parameter
System of units
#3 b5, b4 #37 b5, b4 Position data multiplier
#3 b6 #37 b6 Acceleration/deceleration mode
#3 b8 #37 b8 Pulse output format
#3 b9 #37 b9 Rotation direction
#3 b11 #37 b11 Limit deceleration mode
#3 b14 #37 b14 STOP input polarity
#5, #4 #39, #38 Maximum speed
#6 #41, #40 Bias speed
#8, #7 #43, #42 JOG speed
#15 - Acceleration/deceleration time
- #51 Acceleration time
- #52 Deceleration time
#25 b4
Operation command
Forward JOG operation
#25 b5 Reverse JOG operation
#56, #55 Operation speed change value