144
APPX
Appendix 3 Buffer Memory
*1 The value in 'Block assurance specification per connection' (Un\G16629) is reflected.
Do not write data to "System area". Doing so may cause malfunction of the programmable controller system.
394048 60340H UCMM data link receive
command (No.1)
Result storage area 0 Read
394049 to 394050 60341H to 60342H Target IP Address 0 Read
394051 60343H Service 0 Read
394052 to 394053 60344H to 60345H System area
394054 60346H Class 0 Read
394055 60347H Instance 0 Read
394056 60348H Attribute 0 Read
394057 60349H Data length 0 Read
394058 to 394079 6034AH to 6035FH System area
394080 to 394786 60360H to 60622H Receive data 0 Read
394787 to 394815 60623H to 6063FH System area
394816 to 442431 60640H to 6C03FH UCMM data link request command (No.2 to No.32)
UCMM data link receive command (No.2 to No.32)
0
442432 to 2097151 6C040H to 1FFFFFH System area
Address (decimal) Address
(hexadecimal)
Name Initial
value
Read, write