2 PARAMETER SETTINGS
2.3 Application Setting
45
2
2.3
Application Setting
Configure the Class1 communication auxiliary setting.
Class1 communication supplementary setting
Set the block data assurance per connection.
*1 Cannot be set when "Mode Settings" is set to "Automatically H/W Test" under "Basic Setting".
*2 When "Enable" is set and the module FB is not used, it is necessary to read input data and write output data using 'Class1 Connection
Input data update state' (Un\G32768 to Un\G33023) and 'Class1 Connection Output data update state' (Un\G33024 to Un\G33279).
Item Description Setting range
Block assurance per connection
*1
Sets whether to perform data assurance per connection during Class1
communications.
Set this item to "Enable" and use the following module function blocks to prevent data
inconsistency.
M+RJ71EIP91_Class1GetInputData
M+RJ71EIP91_Class1SetOutputData
Disable
Enable
*2
(Default: Disable)