1 FUNCTIONS
1.3 IP Packet Transfer Function
61
1
When request source and destination devices are connected to RJ71EN71
The results are based on measurement when FTP communications are performed with four modules connected in star
topology.
System configuration (RJ71EN71, RJ71GF11-T2)
When "Port 1 Network Type" and "Port 2 Network Type" is set to "Ethernet" for the RJ71EN71
Measurement result of the communication speed
The following table lists the time that takes until a file is read from a request source device to a request destination device.
(1) RJ71EN71 ("Port 1 Network Type" and "Port 2 Network Type" is set to "Ethernet")
(2) RJ71GF11-T2
Device Description
Ethernet device (request source device) <FTP client> Same as those when a request source device and a request destination
device are connected to a CPU module ( Page 60 When request source
and destination devices are connected to a CPU module)
Ethernet device (request destination device) <FTP server>
Programmable controller
Size of a file to be communicated Time
1K bytes 10ms
50K bytes 100ms
100K bytes 200ms
1M bytes 2000ms
EthernetEthernet
(1) (2)
(1) (2)
Ethernet device (request destination device)
<FTP server>
Ethernet device (request source device)
<FTP client>

Table of Contents