3.11 Grounding 
 WARNING 
Ground the servo amplifier and servo motor securely. 
To prevent an electric shock, always connect the protective earth (PE) terminal 
(marked 
) of the servo amplifier to the protective earth (PE) of the cabinet. 
 
 
The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending on 
the wiring and ground cable routing, the servo amplifier may be affected by the switching noise (due to di/dt 
and dv/dt) of the transistor. To prevent such a fault, refer to the following diagram and always ground. 
To conform to the EMC Directive, refer to the EMC Installation Guidelines (IB(NA)67310). 
 
ᔅߕࠨࡏࠕࡦࡊ
ߩ
PE┵ሶߦធ⛯
ߒߡߊ
ߛߐ
ޕ
ᓮ⋚ߩ⼔ធ
ߦ
⋥ធធ⛯ߒߥߢߊ
ߛߐ
ޕ
PE┵ሶߦធ⛯
ߒߡ
ࠗ
ࡦ
ࡈ
ࠖ
࡞
࠲
(ᵈ)
㔚Ḯ
V
U
ᓮ⋚
ࠨࡏࡕ࠲
M
U
V
W
W
ࠛࡦ
ࠦ࠳
CN2
ࠨࡏࠕࡦࡊ
L11
L1
L2
L3
L21
CN1A
⼔ធ(PE)
ᄖ▫
MC
MCCB
ࠪ
ࠤ
ࡦ
ࠨ
 
Note. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. For power supply 
specifications, refer to section 1.3. 
 
 
Cabinet
Servo amplifier
Servo motor
  CN1
        Line filter
Programmable 
controller
Encoder
(Note) 
Power supply
Protective earth (PE)
Outer 
box
Ensure to connect the wire to the PE 
terminal of the servo amplifier. 
Do not connect the wire directly to  
the grounding of the cabinet.