11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 30
11.6 Junction terminal block MR-TB50
(1) Usage
Always use the junction terminal block (MR-TB50) with the option cable (MR-J2M-CN1TBL_M) as a set.
ࢧ࣮࣎ࣥࣉ
CN1
୰⥅➃Ꮚྎ
MR-TB50
୰⥅➃Ꮚྎࢣ࣮ࣈࣝ
(MR-J2M-CN1TBL_M)
ࢣ࣮ࣈࣝࢡࣛࣥࣉ
Ground the option cable on the junction terminal block side with the cable clamp fitting (AERSBAN-
ESET). For the use of the cable clamp fitting, refer to section 11.14, (2)(c).
(2) Terminal labels
Use the following junction terminal block labels. This label is supplied with the junction terminal block
MR-TB50.
SONP15R LG LAR LBR LZR PG PC RES
DICOM
ZSP TLC TLA OP NP CR LSP LOP
DOCOM
RD
LA LB LZ PP OPC TL INP INP LG LG NG EMG LSN ALM SD
DICOM
LG
DOCOM
⨨ไᚚ࣮ࣔࢻ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
SONP15R LG LAR LBR LZR ST1 RES
DICOM
ZSP TLC TLA OP SP1 LSP LOP
DOCOM
RD
LAVC LB LZ ST2 SA SASP2 LG LG EMG LSN ALM SD
DICOM
LG
DOCOM
㏿ᗘไᚚ࣮ࣔࢻ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
SONP15R LG LAR LBR LZR SR2 RES
DICOM
ZSP VLC TC OP SP1 LOP
DOCOM
RD
LAVLA LB LZ RS1SP2 LG LG EMG ALM SD
DICOM
LG
DOCOM
ࢺࣝࢡไᚚ࣮ࣔࢻ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
(3) Dimensions
235
50
25 (25)
9
2
1
50
49
[
༢: mm]
MITSUBISHI
MR-TB50
2-ȭ4.5
➃Ꮚࡡࡌ: M3.5
㐺ྜ㟁⥺: 2mm
2
ᅽ╔➃Ꮚᖜ: 7.2mm௨ୗ
244
2.5
46.5
1 3 5 7 9 11 13 15 1719 212325 2729 3133
2 4 6 8 10 1214 1618 2022 24 26 28 3032
35 3739 4143 45 47 49
34 36 3840 4244 4648 50
Servo amplifier
Junction terminal block
Cable clamp
Junction terminal block cable
Position control mode
Speed control mode
Torque control mode
[Unit: mm]
Terminal screw: M3.5
Applicable wire: 2 mm
2
Crimp terminal width: 7.2 mm or less.