3. SIGNALS AND WIRING 
3 -  21 
 
3.5 Signal (device) explanations 
For the I/O interfaces (symbols in I/O division column in the table), refer to section 3.9.2. In the control mode 
field of the table 
P: position control mode, S: speed control mode, T: torque control mode 
ż: devices used with initial setting status, : devices used by setting [Pr. PA04] and [Pr. PD03] to [Pr. PD28] 
The pin numbers in the connector pin No. column are those in the initial status. 
 
(1) I/O device 
(a) Input device 
 
Control 
mode 
Device Symbol 
Connect
or pin 
No. 
Function and application 
I/O 
divisi
on 
PST
Turn off EM2 (open between commons) to decelerate the servo motor to a 
stop with commands. 
Turn EM2 on (short between commons) in the forced stop state to reset 
that state. 
The following shows the setting of [Pr. PA04]. 
 
 Deceleration method  
 
[Pr. 
PA04] 
setting 
EM2/EM1
EM2 or EM1 is off  Alarm occurred 
 
 
0 _ _ _  EM1 
MBR (Electromagnetic 
brake interlock) turns 
off without the forced 
stop deceleration. 
MBR (Electromagnetic 
brake interlock) turns 
off without the forced 
stop deceleration. 
 
 
2 0 _ _  EM2 
MBR (Electromagnetic 
brake interlock) turns 
off after the forced 
stop deceleration. 
MBR (Electromagnetic 
brake interlock) turns 
off after the forced 
stop deceleration. 
 
Forced stop 2  EM2  CN1-42 
 
EM2 and EM1 are mutually exclusive. 
EM2 has the same function as EM1 in the torque control mode. 
DI-1 
Forced stop 1  EM1  (CN1-42)  When using EM1, set [Pr. PA04] to "0 _ _ _" to enable EM1. 
Turn EM1 off (open between commons) to bring the motor to an forced 
stop state. The base circuit is shut off, the dynamic brake is operated and 
decelerate the servo motor to a stop. 
Turn EM1 on (short between commons) in the forced stop state to reset 
that state. 
DI-1 
Servo-on  SON  CN1-15  Turn SON on to power on the base circuit and make the servo amplifier 
ready to operate. (servo-on command) 
Turn it off to shut off the base circuit and coast the servo motor. 
Set "_ _ _ 4" in [Pr. PD01] to switch this signal on (keep terminals 
connected) automatically in the servo amplifier. 
DI-1 
Reset  RES  CN1-19  Turn on RES for more than 50 ms to reset the alarm. 
Some alarms cannot be deactivated by RES (Reset). Refer to section 8.1. 
Turning RES on in an alarm-free status shuts off the base circuit. The base 
circuit is not shut off when " _ _ 1 _ " is set in [Pr. PD30]. 
This device is not designed to make a stop. Do not turn on it during 
operation. 
DI-1 
 
△
division