5. PARAMETERS
5 - 23
Control
mode
No./symbol/name
Setting
digit
Function
Initial
value
[unit]
PST
PB31
VG2B
Speed loop gain
after gain
switching
Set the speed loop gain when the gain switching is enabled.
When you set a value less than 20 rad/s, the value will be the same as [Pr. PB09].
This parameter is enabled only when you select "Manual mode (_ _ _ 3)" of "Gain
adjustment mode selection" in [Pr. PA08].
Setting range: 0 to 65535
0
[rad/s]
PB32
VICB
Speed integral
compensation
after gain
switching
Set the speed integral compensation when the gain changing is valid.
When you set a value less than 0.1 ms, the value will be the same as [Pr. PB10].
This parameter is enabled only when you select "Manual mode (_ _ _ 3)" of "Gain
adjustment mode selection" in [Pr. PA08].
Setting range: 0.0 to 5000.0
0.0
[ms]
PB33
VRF1B
Vibration
suppression
control 1 -
Vibration
frequency after
gain switching
Set the vibration frequency for vibration suppression control 1 when the gain
switching is enabled.
When you set a value less than 0.1 Hz, the value will be the same as [Pr. PB19].
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Vibration suppression control 1 tuning mode selection" in [Pr. PB02] is "Manual
setting (_ _ _ 2)".
"Gain switching selection" in [Pr. PB26] is "Input device (gain switching (CDP))
(_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the
servo motor stops.
Setting range: 0.0 to 300.0
0.0
[Hz]
PB34
VRF2B
Vibration
suppression
control 1 -
Resonance
frequency after
gain switching
Set the resonance frequency for vibration suppression control 1 when the gain
switching is enabled.
When you set a value less than 0.1 Hz, the value will be the same as [Pr. PB20].
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Vibration suppression control 1 tuning mode selection" in [Pr. PB02] is "Manual
setting (_ _ _ 2)".
"Gain switching selection" in [Pr. PB26] is "Input device (gain switching (CDP))
(_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the
servo motor stops.
Setting range: 0.0 to 300.0
0.0
[Hz]
PB35
VRF3B
Vibration
suppression
control 1 -
Vibration
frequency
dumping after
gain switching
Set a dumping of the vibration frequency for vibration suppression control 1 when
the gain switching is enabled.
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Vibration suppression control 1 tuning mode selection" in [Pr. PB02] is "Manual
setting (_ _ _ 2)".
"Gain switching selection" in [Pr. PB26] is "Input device (gain switching (CDP))
(_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the
servo motor stops.
Setting range: 0.00 to 0.30
0.00
damping
damping