1 Functions and configuration 
1 -  5 
 
Model MR-J4-    10A 20A 40A 60A 70A 100A 200A 350A 500A 700A
Protective 
functions 
 
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), 
servo motor overheat protection, 
encoder error protection, regenerative error protection, undervoltage protection, instantaneous 
power failure protection, overspeed protection, 
Error excessive warning 
Safety 
function 
          STO (IEC/EN 61800-5-2)       
Standards certified by 
CB (Note 6) 
EN ISO 13849-1 category 3 PL d, EN 61508 SIL 2, EN 62061 SIL CL 2, and EN 61800-5-2 
SIL 2 
Response 
performance 
    8 ms or less (STO input off ĺ energy shut off)     
Safety 
performance 
(Note 3) Test
pulse 
input (STO) 
 
Test pulse interval: 1 Hz to 25 Hz 
Test pulse off time: Up to 1 ms 
 
CE marking     
LVD: EN 61800-5-1 
EMC: EN 61800-3 
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061 
 
Compliance 
to standards 
UL standard        UL 508C       
Structure (IP rating)   
Natural cooling, 
open (IP20) 
  Force cooling, open (IP20) 
Force cooling, 
open (IP20) 
(Note 4) 
Close mounting (Note 2)  Possible  Impossible 
 
Oper
ation 
  0 ÛC to 55 ÛC (non-freezing)       
 
Ambient 
temperature 
Stora
ge 
 -20 ÛC to 65 ÛC (non-freezing)       
 
Oper
ation 
   
Environment 
Ambient 
humidity 
Stora
ge 
 
90% RH or less (non-condensing) 
 
 Ambience   
Indoors (no direct sunlight), 
free from corrosive gas, flammable gas, oil mist, dust, and dirt 
 
  Altitude          Max. 1000 m above sea level       
 Vibration   5.9 m/s
2
 or less at 10 Hz to 55 Hz (directions of X, Y, and Z axes)   
Mass    [kg] 0.8 0.8 1.0 1.0 1.4 1.4 2.1 2.3 4.0 6.2 
 
Note   1. 
 
 2. 
 
 3. 
 
 4. 
 5. 
 6. 
0.5A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of 
I/O points. 
When closely mounting the servo amplifier of 3.5 kW or less, operate them at the ambient temperatures of 0 ÛC to 45 ÛC or at 
75% or smaller effective load ratio. 
This function diagnoses malfunction of contacts including an external circuit by shortly turning off signals from a controller to 
the servo amplifier at a constant period while input signals of the servo amplifier are on. 
Except for the terminal block. 
The rated current is 2.9 A when the servo amplifier is used with UL or CSA compliant servo motor. 
Available in the future.