1 Functions and configuration
1 - 5
Model MR-J4- 10A 20A 40A 60A 70A 100A 200A 350A 500A 700A
Protective
functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal),
servo motor overheat protection,
encoder error protection, regenerative error protection, undervoltage protection, instantaneous
power failure protection, overspeed protection,
Error excessive warning
Safety
function
STO (IEC/EN 61800-5-2)
Standards certified by
CB (Note 6)
EN ISO 13849-1 category 3 PL d, EN 61508 SIL 2, EN 62061 SIL CL 2, and EN 61800-5-2
SIL 2
Response
performance
8 ms or less (STO input off ĺ energy shut off)
Safety
performance
(Note 3) Test
pulse
input (STO)
Test pulse interval: 1 Hz to 25 Hz
Test pulse off time: Up to 1 ms
CE marking
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
Compliance
to standards
UL standard UL 508C
Structure (IP rating)
Natural cooling,
open (IP20)
Force cooling, open (IP20)
Force cooling,
open (IP20)
(Note 4)
Close mounting (Note 2) Possible Impossible
Oper
ation
0 ÛC to 55 ÛC (non-freezing)
Ambient
temperature
Stora
ge
-20 ÛC to 65 ÛC (non-freezing)
Oper
ation
Environment
Ambient
humidity
Stora
ge
90% RH or less (non-condensing)
Ambience
Indoors (no direct sunlight),
free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude Max. 1000 m above sea level
Vibration 5.9 m/s
2
or less at 10 Hz to 55 Hz (directions of X, Y, and Z axes)
Mass [kg] 0.8 0.8 1.0 1.0 1.4 1.4 2.1 2.3 4.0 6.2
Note 1.
2.
3.
4.
5.
6.
0.5A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
When closely mounting the servo amplifier of 3.5 kW or less, operate them at the ambient temperatures of 0 ÛC to 45 ÛC or at
75% or smaller effective load ratio.
This function diagnoses malfunction of contacts including an external circuit by shortly turning off signals from a controller to
the servo amplifier at a constant period while input signals of the servo amplifier are on.
Except for the terminal block.
The rated current is 2.9 A when the servo amplifier is used with UL or CSA compliant servo motor.
Available in the future.