1 Functions and configuration
1 - 13
(4) MR-J4-700A
POINT
The servo amplifier is shown without the front cover. For removal of the front
cover, refer to section 1.6.2.
No. Name/Application
Detailed
explanati
on
(1)
Power factor improving reactor terminal block (TE3)
Used to connect the DC reactor.
(2)
Main circuit terminal block (TE1)
Used to connect the input power supply,
regenerative option, and servo motor.
(3)
Control circuit terminal block (TE2)
Used to connect the control circuit power supply.
(4)
Protective earth (PE) terminal
Ground terminal.
Section
3.1
Section
3.3
(5)
Battery holder
Install the the battery for absolute position data
backup.
Chapter
12
(6)
Rating plate Section
1.6
(7)
Charge lamp
Lit to indicate that the main circuit is charged. While
this lamp is lit, do not reconnect the cables.
(1)
(5)
(2)
()
(4) (3)
(6)
◚⥺ෆࡣMR-J4-200
A
ୗ࡜ඹ㏻࡛ࡍࠋ
(7)
Note. Lines around the battery holder are omitted from the illustration.
The broken line area is the same as MR-J4-200A or less.
(Note)
Section
12.4

Table of Contents