11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 21
(2) FR-BR Resistor unit
[Unit: mm]
H3 ± 1
H1 ± 3
Approx.
H2
Approx.
H2
D1
H ± 5
Control circuit
terminal
Main circuit
terminal
W1 ± 1
Approx. 35
Approx. 35
C
C
W ± 5
D ± 5
(Note)
(Note)
Note. Ventilation ports are provided on both sides and the top. The bottom is open.
Resistor unit W W1 H H1 H2 H3 D D1 C
Approximate
mass [kg]
FR-BR-15K 170 100 450 410 20 432 220 3.2 6 15
200 V
class
FR-BR-30K 340 270 600 560 20 582 220 4 10 30
11.4 FR-RC Power regenerative converter
POINT
When using FR-RC, set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1).
When using the power regenerative converter, set "_ _ 0 1" in [Pr. PA02].
(1) Selection example
The converters can continuously return 75% of the nominal regenerative power. They are applied to the
servo amplifiers of the 5 kW to 7 kW.
Power regenerative
converter
Nominal
regenerative
power
[kW]
Servo amplifier
FR-RC-15K 15 MR-J4-500A
FR-RC-30K 30 MR-J4-700A
Nominal regenerative power [%]
50 75 100 150
0
500
300
200
100
50
30
20
Continuous energization time [s]