8 - 35
8 OUTPUT MODULE
(f) An example of an address mode clutch operation is shown below.
10000
10000
0
0
00
0
00
0000
1 axis
Number of pulses per revolution : 10000[PLS]
Cam
Set the clutch ON/OFF in this current value.
(Current value within 1 virtual axis revolution)
Virtual servomotor current value
(Synchronous encoder)
Current value within 1 virtual
axis revolution
Set the clutch status
Clutch ON address = 0
Clutch OFF address = 0
Cam pattern(Stroke amount)
Current value within 1 output
axis revolution
Operation example