4 - 3
4 POSITIONING DEDICATED SIGNALS
4.1 Internal Relays
(1) Internal relay list
SV22
Device No. Application Real Virtual
M0
to
User device
(2000 points)
M2000
to
Common device
(320 points)
M2320
to
Unusable
(80 points)
M2400
to
Axis status
(20 points
32 axes)
Real mode : Each axis
Virtual mode : Output module
M3040
to
Unusable
(32 points)
M3072
to
Common device
(Command signal)
(64 points)
M3136
to
Unusable
(64 points)
M3200
to
Axis command signal
(20 points
32 axes)
Real mode : Each axis
Virtual mode : Output module
M3840
to
Unusable
(160 points)
M4000
(Note-1)
to
Virtual servomotor axis status
(20 points
32 axes)
(Note-2)
Backup
M4640
(Note-1)
to
Synchronous encoder axis
status
(4 points
12 axes)
M4688
(Note-1)
to
Unusable
(112 points)
M4800
(Note-1)
to
Virtual servomotor axis
command signal
(20 points
32 axes)
(Note-2)
M5440
(Note-1)
to
Synchronous encoder axis
command signal
(4 points
12 axes)
(Note-4)
M5488
to
M8191
User device
(Note-3)
(2704 points)
: Valid, : Invalid
It can be used as a user device.
Real/virtual
community
Virtual