Table 1.16 Output Module Error List (4000 to 5990) (Continued)
Output module
Error
class
Error
code
Roller
Ball
screw
Rotary
table
Cam
Error cause Processing Corrective action
5220
• The first clutch OFF address setting
device is an odd number.
Related system
cannot be
started.
5230
• The first current value within 1 virtual
axis revolution storage device (main
shaft side) is an odd number.
5240
• The first current value within 1 virtual
axis revolution storage device
(auxiliary input shaft side) is an odd
number.
Operation is
possible, but
monitoring is
impossible.
• Set an even numbered the first
device.
5250
• When the amount of slip is set as the
clutch smoothing method, the amount
of slip setting device value is outside
the range (0 to 2147483647).
Amount of slip =
0 (control as the
direct clutch).
• Set a value within the range of 0
to 2147483647.
5260
• The device set to "Stroke amount
setting device" is outside the range.
• Correct the device set to
"Stroke amount setting device".
5270
• The device set to "Cam No. setting
device" is outside the range.
• Correct the device set to Cam
No.
5280
• The device set to "Clutch mode setting
device" is outside the range.
• Correct the device set to clutch
mode.
5290
• The device set to "Clutch ON address
setting device" is outside the range.
• Correct the device set to clutch
ON address.
5300
• The device set to "Clutch OFF address
setting device" is outside the range.
• Correct the device set to clutch
OFF address.
5310
• The device set to "Clutch ON/OFF
command setting device" is outside
the range.
• Correct the device set to clutch
ON/OFF command.
5320
• The device set to "Speed change ratio
setting device" is outside the range.
Related system
cannot be
started.
• Correct the device set to speed
change ratio.
5330
• The device set to "Amount of slip
setting device" is outside the range.
Amount of slip =
0 (control as the
direct clutch).
• Correct the device set to
amount of slip.
5340
• The device set to "Torque limit value
setting device" is outside the range.
Related system
cannot be
started
• Correct the device set to torque
limit value.
5350
• The device set to "Current value within
1 virtual axis revolution storage device
(main shaft side)" is outside the range.
Current value
within 1 virtual
axis revolution
(main shaft side)
cannot be
monitored.
• Correct the device set to current
value within 1 virtual axis
revolution (main shaft side).
5360
• The device set to "Current value within
1 virtual axis revolution storage device
(auxiliary input axis side) storage
device" is outside the range.
Current value
within 1 virtual
axis revolution
(auxiliary input
axis side) cannot
be monitored.
• Correct the device set to current
value within 1 virtual axis
revolution (auxiliary input axis
side).
5370
• The device set to "Lower stroke limit
value storage device" is outside the
range.
Lower stroke
limit value
cannot be
monitored.
• Correct the device set to lower
stroke limit value.
Minor
error
5380
• The device set to "Number of input
axis side gear tooth count setting
device" is outside the range.
Related system
cannot be
started.
• Correct the device set to
number of input axis side gear
tooth count.