EasyManua.ls Logo

Mitsubishi Electric Q172DCPU - Page 81

Mitsubishi Electric Q172DCPU
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 60
2 SYSTEM CONFIGURATION
(6) Connection examples of manual pulse generator
Connection of manual pulse generator Connection of manual pulse generator
(Voltage-output/Open collector type) (Differential-output type)
SG
SG
Q173DPX
SG
P5
Signal name
A
A
B
0V
5V
SG
P5
A
B
0V
5V
B
Manual pulse
generator side
FG
FG
SG
shield
(Note-2)
: 1 to 3
HA
HB
Q173DPX
Manual pulse
generator side
Signal name
: 1 to 3
HA P
HA N
HB P
HB N
HPSEL
(Note-2)
(Note-1)
(Note-1)
:Twisted pair cable
:Twisted pair cable
(Note-1) : The 5V(P5)DC power supply from the Q173DPX must not be connected if a separated
power supply is used as the Manual pulse generator/Incremental synchronous
encoder power supply.
Use a 5V stabilized power supply as a separated power supply. Any other power supply
may cause a failure.
(Note-2) : Connect HPSEL to the SG terminal if the manual pulse generator (differential output
type/incremental synchronous encoder is used.
CAUTION
If a separate power supply is used as the manual pulse generator/incremental synchronous
encoder power supply, use a 5V stabilized power supply. Any other power supply may cause a
failure.

Table of Contents

Other manuals for Mitsubishi Electric Q172DCPU

Related product manuals