EasyManua.ls Logo

Mitsubishi Electric Q26UD(E)HCPU - Page 515

Mitsubishi Electric Q26UD(E)HCPU
720 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
513
APPENDICES
A
Appendix 3 List of Special Register Areas
SD16 to
SD26
Error
individual
information
Error
individual
information
This register stores individual information corresponding to
the error code stored in SD0.
There are the following eight different types of information
are stored.
The error individual information type can be determined by
"individual information category code" stored in SD4.
(Values stored in "individual information category code"
correspond to the following 1) to 9), 12), and 13).)
1) (Empty)
2) File name/drive name
3) Time (value actually measured)
4) Program error location
*6 For extension names, refer to the table on Page 511,
Appendix 3 (1) (a).
*7 The description of the bit pattern is as follows:
S (Error) New
QCPU
LCPU
Number Name Meaning Explanation
Set by
(When Set)
Corresponding
ACPU
D9
Corresponding
CPU
SD16
SD17
SD18
SD19
SD20
SD21
SD22
SD23
SD24
SD25
SD26
6
ABCDEFGH. IJK
42H(B) 41H(A)
44
H(D) 43H(C)
46
H(F) 45H(E)
48
H(H) 47H(G)
49
H(I) 2EH(.)
4B
H(K) 4AH(J)
b15 to b8 b7 to b0
Number Meaning
Drive
File name
(ASCII code: 8 characters)
Extension
2E
H(.)
(ASCII code: 3 characters)
(Empty)
(Example) File name =
SD16
SD17
SD18
SD19
SD20
SD21
SD22
SD23
SD24
SD25
SD26
Number Meaning
Time : 1 s units (0 to 999 s)
Time : 1ms units (0 to 65535ms)
(Empty)
SD16
SD17
SD18
SD19
SD20
SD21
SD22
SD23
SD24
SD25
SD26
Number Meaning
File name
(ASCII code: 8 characters)
Extension 6
2E
H(.)
(ASCII code: 3 characters)
Pattern 7
Block No.
Step No./transition No.
Sequence step No. (L)
Sequence step No. (H)
0000
to
0
12
3
4
15
14 to
(Not used)
(Bit number)
SFC block designation present (1)/absent (0)
SFC step designation present (1)/absent (0)
SFC transition designation present (1)/absent (0)

Table of Contents

Related product manuals