EasyManua.ls Logo

Mitsubishi Electric QD77MS - 2-Axis Circular Interpolation Control with Center Point Designation

Mitsubishi Electric QD77MS
1052 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 - 68
Chapter 9 Major Positioning Control
9.2.11 2-axis circular interpolation control with center point designation
In "2-axis circular interpolation control" ("[Da.2] Control method" = ABS circular right,
INC circular right, ABS circular left, INC circular left), two motors are used to carry out
position control in an arc path having an arc address as a center point, while carrying
out interpolation for the axis directions set in each axis.
(Refer to Section 9.1.6 "Interpolation control" for details on interpolation control.)
The following table shows the rotation directions, arc center angles that can be
controlled, and positioning paths for the different control methods.
Control method Rotation direction
Arc center angle that
can be controlled
Positioning path
ABS circular right
Clockwise
0
°
<
360
°
Positioning path
0° < < 360°
Center point
Start point
(current stop
position)
End point
(positioning address)
INC circular right
ABS circular left
Counterclockwise
Center point
Positionin
g
p
ath
Start point
(current stop
position)
End point
(positioning address)
0°< < 360°
INC circular left

Table of Contents

Related product manuals