Appendix - 29
Appendices
Appendix 2.1 SSCNET cables
Generally use the SSCNET
cables available as our products.
Refer to Appendix 2.3 for long distance cable up to 100[m] and ultra-long bending life
cable.
(1) Model explanation
Numeral in the column of cable length on the table is a symbol put in the "_" part
of cable model. Cables of which symbol exists are available.
Table 2.1 SSCNET cable list
Cable model
Cable length [m(ft.)]
Bending life
Application/
remark
0.15
(0.49)
0.3
(0.98)
0.5
(1.64)
1
(3.28)
3
(9.84)
5
(16.40)
10
(32.81)
20
(65.62)
30
(98.43)
40
(131.23)
50
(164.04)
MR-J3BUS_M 015 03 05 1 3 Standard
Standard cord for
inside panel
MR-J3BUS_M-A 5 10 20 Standard
Standard cable for
outside panel
MR-J3BUS_M-B
(Note-1)
30 40 50
Long bending
life
Long distance
cable
(Note-1): For the cable of less than 30m (98.43ft.), contact your nearest Mitsubishi sales representative.
(2) Specification
Table 2.2 SSCNET cable list
Description
SSCNET cable model MR-J3BUS_M MR-J3BUS_M-A MR-J3BUS_M-B
SSCNET cable length [m(ft.)]
0.15
(0.49)
0.3 to 3
(0.98 to 9.84)
5 to 20
(16.40 to 65.62)
30 to 50
(98.43 to 164.04)
Optical cable
(Cord)
Minimum bend radius
[mm(inch)]
25(0.98)
Enforced covering cord: 50 (1.97)
Cord: 25 (0.98)
Enforced covering cord: 50 (1.97)
Cord: 30(1.18)
Tension strength [N] 70 140 420 (Enforced covering cord) 980 (Enforced covering cord)
Temperature range
for use [°C(°F)]
(Note-1)
-40 to 80
(-40 to 176)
-20 to 70
(-4 to 158)
Ambient Indoors (no direct sunlight), No solvent or oil
External appearance
[mm(inch)]
(0.09 0.003)
2.2 0.07
10.16
(Note-2)
(0.40)
4.4 0.1
(0.17 0.004)
(0.09 0.003)
2.2 0.07
(
0.09 0.003
)
2.2 0.07
4.4 0.1
(0.17 0.004)
6 0.2
(0.24 0.008)
4.4 0.4
(0.17 0.016)
7.6 0.5
(0.30 0.02)
(
0.09 0.008
)
2.2 0.2
(Note-1): This temperature range for use is the value for optical cable (cord) only.
(
Note-2): Dimension of connector fiber insert location. The distance of two cords is changed by how to bend it.