3-80
3 Controller
■Pin arrangement of the connector
Fig.3-31: Pin arrangement of the parallel I/O unit
■Assignment of pin number and signal
The assignment range of the general-purpose input-and-output signal is fixed by the setup of the station
number.
Although the combined use with the parallel I/O interface (2D-TZ368/2D-TZ378) of another option is also
possible, please use the setup of the station number by the different number separately.
Table 3-31: Assignment of pin number and signal
The connector pin number of the parallel I/O unit of the station number 0 and signal number assignment are
shown in Table 3-32 and Table 3-33. If it is set as other station number, please interpret and utilize.
Unit Number
Station
number
CN100 CN300
1st set 0 Input: 0 to 15
Output: 0 to 15
Input: 16 to 31
Output: 16 to 31
2nd set 1 Input: 32 to 47
Output: 32 to 47
Input: 48 to 63
Output: 48 to 63
3rd set 2 Input: 64 to 79
Output: 64 to 79
Input: 80 to 95
Output: 80 to 95
4th set 3 Input: 96 to 111
Output: 96 to 111
Input: 112 to 127
Output: 112 to 127
5th set 4 Input: 128 to 143
Output: 128 to 143
Input: 144 to 159
Output: 144 to 159
6th set 5 Input: 160 to 175
Output: 160 to 175
Input: 176 to 191
Output: 176 to 191
7th set 6 Input: 192 to 207
Output: 192 to 207
Input: 208 to 223
Output: 208 to 223
8th set 7 Input: 224 to 239
Output: 224 to 239
Input: 240 to 255
Output: 240 to 255
50
26
25
1
Channel No. setting
TXD
LED display
Input 0 to 15
Output 0 to 15
<CN100>
<CN300>
Input 16 to 31
Output 16 to 31
*2A-RZ361/2 A-RZ371 are 32/32 input-and-output units. (One-station occupancy)
*1)
*1)TXD LED display
Indicator for the
communication status. The
dimly lit lamp indicates that
the unit is in the normal
condition. The brightness of
the light depends on the
communication conditions.