EasyManua.ls Logo

Mitsubishi FREQROL-SFJ - 3.9 Parameter list

Mitsubishi FREQROL-SFJ
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.9 Parameter list
c
Parameter
Description
Set;A;&)range
01 NOX Motor type
Set
"0".
Decimal nota-
tion
02 MSL Motor
sel-
SJ-J2.2A
. . . . . 0
Decimal
nota-
ection
SJ-J3.7A
. . . . . 1
tion
SJ-J5.5A
. . . . . 2
SJ-J7.5A
. . . . . 3
03 PLG Position
Setting is made for number of
Decimal
nota-
control
encoder pulses.
tion
loop
encoder
0: 1024 pulses (encoder oriented
type
spindle stop, sync. TAP)
04 MOD External
Setting depends on interface with
Decimal
nota-
interface NC.
tion
mode
sel-
ection
0: Decimal IO (CON1 signal is
used for operation)
2: Bus-line connection to M300
series CNC
05 DSR Digital
Type of digital speed reference
Decimal
nota-
speed
re-
signal is selected.
tion
ference
This parameter is valid when MOD
signal type
(#04)
is
set
llo,,.
0: 12-bit binary
1:
Signed
12-bit
binary
2: BCD
(2-digit)
3: BCD
(3-digit)
06 MON Output
Type of meter for monitor
(MO2
Decimal
nota-
monitor
output of
CONl)
is set.
tion
selection
0:
Load meter
1:
Torque meter
Standard setting: 0
07
OlSL
Auxiliary
0: Speed detection ON
0 -- 4
output 1
selection
1:
Torque limit ON
2: Spindle control ready
3: Emergency stop ON
4: Alarm ON
08
02SL
Auxiliary 0: Speed detection ON
0
-4
output 2
selection
1:
Torque
*limit
ON
2:
Spindle control ready
3: Emergency stop ON
4:
Alarm ON
-
42
-

Table of Contents